Product Code: SYT-503 syringe pump
- Double-channels(multi-channels), sub-rate injection.
● Four kinds of injection modes: Rate mode, Time mode, Body Weight mode,
link mode.
● Innovative design of outer appearance gives a strong sense of science and
technology.
● Double CPU makes the process of injection safer and more reliable.
● The use of TFT color LCD makes the screen display more remarkable.
● Digital menu, easy operation; functions fully meet the clinical demand.
● Integrative pump device makes more smooth operation and easier installation and maintenance.
● Brand-new STM32 ARM-Cortex M3 platform, optimized circuit design, operation rate
more faster and stable.
● Ample and user-friendly indicator information; accurate and complete alarm
information to ensure safe injection.
● Unique wireless infusion supervision function, achieving accurate infusion and synchronization infusion supervision to patients.
Max. injection rate | 1500ml/h(Different injectors have different maximum rate.) | Accumulated volume | 0.1ml~999.9ml |
Max. size of outer shell | 320 mm×200 mm×110 mm(length×width×height) | Injection accuracy | ±3% ( up to +1% after calibration.) |
Applicable injectors | 5, 10, 20, 30, 50ml | Injection increment | 0.1ml/h |
Battery | AC 100~240V,50/60Hz | Volume limit | 0.1ml~999.9ml |
Battery recharge | Rechargeable Lithium Polymer battery, 7.4V, 1600mA | Classification | ClassⅡ, Type BF |
Max. power consumption | Single-channel works for continuous 5 hours at the rate of 25ml/h after fully recharged; double-channels works for continuous 3 hours at the rate of 25ml/h after fully recharged. | ||
Range of flow rate | 5ml injector: 0.1ml/h~100ml/h 10ml injector:0.1ml/h~200ml/h
20ml injector:0.1ml/h~400ml/h 30ml injector:0.1ml/h~600ml/h 50ml injector:0.1ml/h~1500ml/h |
||
Bolus rate | 5ml injector: 100ml/h 10ml injector:200ml/h
20ml injector:400ml/h 30ml injector:400~600ml/h (adjustable) 50ml injector:400~1500ml/h(adjustable) |
||
Alarm information | Near completion, completion, OCCL., injector off, low voltage, No AC Power supply, communication error, link abnormal, pump stuck, reading error of the parameters, etc. | ||
Mode selection | 1. Rate mode 2. Time mode 3. Body Weight mode 4. Link mode | ||
Rate mode | Rate:0.1ml/h~1500.0ml/h(Max. value depends on injector specification) | ||
Time mode | Volume:0.1ml~999.9ml Time:1min.~2000 min. | ||
Body Weight mode | Weight:0.1kg~300.0kg drug:0.1mg~999.9mg volume:0.1ml~999.9ml
dose:0.1~1500.0 (restricted to unit, drug, solution, weight and injector) Unit:mg/kg/h, ug/kg/min |
||
OCCL. value | 40Kpa~160Kpa,display the voltage status and the pressure value. | ||
KVO rate | Adjustable range:0.1ml/h~5.0ml/h(adjustable: 0.1ml/h per each segment,press “0” to cancel KVO function.) |