Infant Incubator

Email: sales@clovermedical.net   Website: www.clover-surgical.com

Home Titanium Bipolar Forceps  Medical Equipment Hospital Furniture Medical Disposable About Us Photo Gallery Contact Us   English    中文
 

 

Product Code: SYS-100S, Infant Incubator

Main functions:

◎ Microprocessor based servo controlled temperature system
◎ Temperature displayed by LED
◎ Alarm functions : Power failure; over temperature; temperature deviation; temperature sensor failure;fan failure;
◎ >37℃ temperature setting
◎ A keypad lock helps prevent inadvertent changes the setting
◎ Temperature deviation and over temperature could be amended in front panel directly
◎ The infant bed inclination angle is adjustable
◎ Humidity is adjustable continuously
◎ Integral timer to record therapy time
◎ A second thermal cut-off function for more safety

Product Code: SYS-100L, Infant Incubator

Main functions:

◎ Microprocessor based servo controlled temperature system
◎ Temperature displayed by LED
◎ Alarm functions : Power failure; over temperature; temperature deviation; temperature sensor failure;fan failure;
◎>37℃ temperature setting
◎ A keypad lock helps prevent inadvertent changes the setting
◎ Temperature deviation and over temperature could be amended in front panel directly
◎ The infant bed inclination angle is adjustable
◎ Humidity is adjustable continuously
◎ Integral timer to record therapy time
◎ A second thermal cut-off function for more safety

Product Code: SYS-100T, Infant Incubator

Main functions:

◎ Microprocessor based servo controlled temperature system
◎ Temperature displayed by LED
◎ Alarm functions : Power failure; over temperature; temperature deviation; temperature sensor failure;fan failure;
◎ >37℃ temperature setting
◎ A keypad lock helps prevent inadvertent changes the setting
◎ Temperature deviation and over temperature could be amended in front panel directly
◎ The infant bed inclination angle is adjustable
◎ Humidity is adjustable continuously
◎ Integral timer to record therapy time
◎ A second thermal cut-off function for more safety

Product Code: SYS-200S, Infant Incubator

Main functions:

◎ Microprocessor based servo controlled temperature system
◎ Air temperature,skin temperature,timer and heat power separately displayed by LED
◎ Alarm functions : Power failure; over temperature; temperature deviation; temperature sensor failure;fan failure;
◎ >37℃ temperature setting
◎ A keypad lock helps prevent inadvertent changes the setting
◎ Temperature deviation and over temperature could be amended in front panel directly
◎ The infant bed inclination angle is adjustable
◎ Humidity is adjustable continuously
◎ Integral timer to record therapy time
◎ Skin temperature sensor failure protect function avoid over temperature
◎ A second thermal cut-off function for more safety

Product Code: SYS-200L, Infant Incubator

Main functions:

◎ Microprocessor based servo controlled temperature system
◎ Air temperature,skin temperature,timer and heat power separately displayed by LED
◎ Alarm functions : Power failure; over temperature; temperature deviation; temperature sensor failure;fan failure;
◎ >37℃ temperature setting
◎ A keypad lock helps prevent inadvertent changes the setting
◎ Temperature deviation and over temperature could be amended in front panel directly
◎ The infant bed inclination angle is adjustable
◎ Humidity is adjustable continuously
◎ Integral timer to record therapy time
◎ Skin temperature sensor failure protect function avoid over temperature
◎ A second thermal cut-off function for more safety

Product Code: SYS-300S, Infant Incubator

Main functions:

◎ Microprocessor based servo controlled temperature system
◎ Air temperature,skin temperature,humidity,timer and heat power separately displayed by LED
◎ Alarm functions : Power failure; over temperature; temperature deviation; temperature sensor failure;fan failure;
◎ >37℃ temperature setting
◎ A keypad lock helps prevent inadvertent changes the setting
◎ Temperature deviation and over temperature could be amended in front panel directly
◎ The infant bed inclination angle is adjustable
◎ Humidity is adjustable continuously
◎ Integral timer to record therapy time
◎ Skin temperature sensor failure protect function avoid over temperature
◎ A second thermal cut-off function for more safety

Product Code: SYS-300L,  Infant Incubator

Main functions:

◎ Microprocessor based servo controlled temperature system
◎ Air temperature,skin temperature,humidity,timer and heat power separately displayed by LED
◎ Alarm functions : Power failure; over temperature; temperature deviation; skin sensor failure;fan failure;
◎ >37℃ temperature setting
◎ A keypad lock helps prevent inadvertent changes the setting
◎ Temperature deviation and over temperature could be amended in front panel directly
◎ The infant bed inclination angle is adjustable
◎ Humidity is adjustable continuously
◎ Integral timer to record therapy time
◎ Skin temperature sensor failure protect function avoid over temperature
◎ A second thermal cut-off function for more safety
◎ Large size and double wall hood
◎ Electric height adjustable suit for operation

Product Code: SYS-N100S, Infant Radiant Warmer

Main functions:

◎Microprocessor based servo controlled temperature system.
◎The microprocessor-controlled unit allows for three settings: pre-warm, manual or automatic.
◎Alarm functions for safety includes: Power failure, temperature deviation,
Temperature sensor failure , over temperature.
◎APGAR timer to record therapy time
◎Convenient X-ray cassette under infant bed
◎Heater head can be adjusted + 90º horizontally
◎Tilt angle of infant bed is adjustable
◎Halogen Observe light angle is adjustable
◎Transparent protector folded
◎Alarms are audible and visual
◎A second thermal cut-out function for more safety
◎Skin temperature sensor failure protect function avoid over temperature

 

Product Code: SYS-N100M, Infant Radiant Warmer

Main functions:

◎Microprocessor based servo controlled temperature system.
◎The microprocessor-controlled unit allows for three settings: pre-warm, manual or automatic.
◎Alarm functions for safety includes:
Power failure, temperature deviation,
Temperature sensor failure , over temperature.
◎APGAR timer to record therapy time
◎Convenient X-ray cassette under infant bed
◎Heater head can be adjusted + 90º horizontally
◎Tilt angle of infant bed is adjustable
◎Halogen Observe light angle is adjustable
◎Transparent protector folded
◎Alarms are audible and visual
◎A second thermal cut-out function for more safety
◎Skin temperature sensor failure protect function avoid over temperature
◎LED phototherapy unit

Product Code: SYS-N100T, Infant Radiant Warmer

Main functions:

Microprocessor based servo controlled temperature system.
◎The microprocessor-controlled unit allows for three settings: pre-warm, manual or automatic.
◎Alarm functions for safety includes:
Power failure, temperature deviation,
Temperature sensor failure , over temperature.
◎APGAR timer to record therapy time
◎Convenient X-ray cassette under infant bed
◎Heater head can be adjusted + 90º horizontally
◎Tilt angle of infant bed is adjustable
◎Halogen Observe light angle is adjustable
◎Transparent protector folded
◎Alarms are audible and visual
◎A second thermal cut-out function for more safety
◎Skin temperature sensor failure protect function avoid over temperature
◎Low pressure aspirator, oxygen supply system and LED phototherapy unit

Product Code: SYS-N100AS, Infant Radiant Warmer

Main functions:

◎Microprocessor based servo controlled temperature system.
◎Alarm functions for safety includes:
 Power failure, temperature deviation,
Temperature sensor failure, over temperature.
◎Alarms are audible and visual
◎A second thermal cut-out function for more safety
◎Skin temperature sensor failure protect function avoid over temperature

Product Code: SYS-N100AT, Infant Radiant Warmer

Main functions:

◎Microprocessor based servo controlled temperature system.
◎The microprocessor-controlled unit allows for three settings: pre-warm, manual or automatic.
◎Alarm functions for safety includes:
 Power failure, temperature deviation,
Temperature sensor failure , over temperature.
◎APGAR timer to record therapy time
◎Convenient X-ray cassette under infant bed
◎Heater head can be adjusted + 90º horizontally
◎Tilt angle of infant bed is adjustable
◎Transparent protector folded
◎Alarms are audible and visual
◎A second thermal cut-out function for more safety
◎Skin temperature sensor failure protect function avoid over temperature

 

Product Code: SYS-N200,  Infant Radiant Warmer

Main functions:

◎Three modes of control: manual, skin temperature and mattress temperature
◎Microprocessor based servo controlled temperature system
◎Control panel displayed by VFD
◎Digital skin temperature sensor, the data is exact and stabilizability
◎High sensitivity and untouched detector to inspect mattress temperature
◎Alarm functions for safety include power failure temperature deviation
temperature probe failure over temperature
◎APGAR timer to record therapy time
◎Observe light angle can be adjusted + 90º, and the brightness adjusted
◎Heater head can be adjusted + 90º horizontally
◎Electric infant bed tilt angle is + 10º, transparent protector folded
◎Convenient X-ray cassette under infant bed
◎Electric height adjusted suit for operation
◎Alarms are audible and visual
◎A second thermal cut-out function for more safety
◎Skin temperature sensor failure protect function avoid over temperature

 

Parturition Table, Obstetric Table, Lying Parturition Table, Ordinary Parturition Table, Ordinary Table, Hospital Table, Examination Table, Gynaecology Examination Table, Gynaecology Table, Electrical Delivery Bed, Delivery Bed, Infant Bed, Baby Bed Infant Incubator, Incubator, Incubators, Neonate Incubator, Neonate Phototherapy, Infant Phototherapy, Infant Radiant Warmer, Infant Warmer, Infant Oven, Baby Incubator, Neonatal Intensive Care Unit, Neonatal Intensive Care, Jaundice Detector, Fetal Monitor, Neonatal Units, Fixable Infant Incubator, Incubator Systems, Premature Baby Incubator, Neotech Infant Incubator, Human Balance