 |
Product Code: KWS
4000 HEMODIAFILTRATION DEVICE (HDF on-line)
Technical Features:
1. The Multi-Functional Machine Offers Customized Curing
Mode For Patients.
2. The Advanced Volume Balance Control System Enables
Accurate Control of Ultrafiltration.
3. Double-Stage Intoxication Filtration Ensuring That
The Substitution Fluid Meets AAMI Standards.
4. Reliable System and Safe Treatment Ensured By
Pressure Detectors, Conductivity Detectors, Air
Detectors and Blood Leakage Detectors
Function Features:
1. Adjustable Sodium And Multi Ultrafiltration Curves
Enable Customized Treatment For Patients.
2. Convenient Process for Sequential Ultrafiltration and
Dialysis.
3. High Volume Hemofiltration (HVHF) Is Available
(Substitution Fluid ≧25l/H).
4. Kt/V Calculation Function Can Be Used For Evaluating
the Sufficiency of Dialysis via the Urea Kinetic Model
Volume Balance System.
5. Isolated Hemoperfusion Mode, Decrease the Normal
Hemodiafiltration Device Self-Detecting Time And The
Dialysate Waste.
6. The Adaptive Regulation and Control System
Effectively Avoids Various Complications. And Can Clear
Middle and Small Molecules Toxin
7. Automatic Disinfestation and Decalcifilcation by Many
Kinds of Disinfectant Liquids and Picking Solutions.
8. The Battery Supplies for the Entire Blood Section
Incl. All Monitoring Devices and Displays for 30 Min.
|
 |
Product Code:
KWS-4000 A HEMODIALYSIS SYSTEM (SINGLE PUMP)
Forms of Therapy:
Hemodialysis, Isolated Ultrafiltration, Sequential
Ultrafiltration, Hemoperfusion
Indication:
Acute and Chronic Renal Failure, Uremia, MODS
(Multiple Organ Dysfunction Syndrome) and
Intoxication.
Functional features:
1. Sodium And Ultrafiltration Profiles Provide
Individual Treatment For Patients.
2. Convenient Program of Sequential Therapy and
Dialysis with Variational Sodium.
3. KT⁄V Calculation Function Evaluates The
Sufficiency Of Dialysis.
4. The Special Hemoperfusion Mode Reduces The Time
For Self Tests And The Consumption Of Water And
Concentrates In Normal Dialysis Machines.
5. Can Provide the Isolated Dialysate
6. The Battery Supplies For The Entire Blood Section
All Monitoring Devices And Displays For 30 Min.
Technical Features:
1. Multifunction, individual therapy
2. The advanced Volume Balance Control System
enables accurate control of ultrafiltration.
3. The combination of sodium profile and
ultrafiltration profile effectively avoids
complications:
Low blood pressure and electrolyte unbalance.
4. Reliability and safety are ensured by a
dual-control-supervising system.
|
 |
Product Code: KWS-4000
HEMODIAFILTRATION SYSTEM(HDF-BAG)
Forms of Therapy:
Hemodialysis, Hemodiafiltration (HDF-Bag),
Isolated Ultrafiltration, Sequential
Ultrafiltration, Hemoperfusion, Plasma Exchange
Indication:
Acute and Chronic Renal Failure, Uremia, MODS
and Intoxication
Technical Features:
1. Multifunction, Individual Therapy.
2. The Advanced Volume Balance Control System
Enables Accurate Control of Ultrafiltration.
3. The Diversified Treatment Modes Can Satisfy
Various Clinical Needs.
4. Reliability And Safety Are Ensured By A
Dual-Control-Supervising System.
Functional Features:
1. Sodium And Ultrafiltration Profiles Provide
Individual Treatment For Patients.
2. Convenient Program of Sequential Therapy and
Dialysis with Variational Sodium.
3. Double Pumps Design, Hemodiafiltration With
Bag Can Satisfy All Kinds Of Clinical Needs.
4. KT⁄V Calculation Function Evaluates The
Sufficiency Of Dialysis.
5. The Special Hemoperfusion Mode Reduces The
Time For Self Tests And The Consumption Of Water
And Concentrates In Normal Dialysis Machines.
6. The Battery Supplies for the Entire Blood
Section Incl. All Monitoring Devices and
Displays for 30 Min.
7. Automatic Disinfection and Decalcification
with All Kinds of Disinfectant and Acid.
8. Convenient, Quick After-Sale Service and Low
Maintenance Cost.
|
|